Norgren M/80 Inline Flow Sensor - IO-Link, 1\" NPT

Part Number: M/80/IOL/25C/CC
Manufacturer
Norgren
Part number
M/80/IOL/25C/CC

Quick Summary

The M/80 Inline Flow Sensor measures compressed air flow, pressure, temperature and total consumption to support real‑time process monitoring in pneumatic systems. It helps eliminate scattered readings and manual data collection by delivering a single IO-Link interface with digital transmission and an integrated TFT display. While the data sheet does not list CE, SIL or IP certifications, the device’s IO-Link capability and German engineering reflect a commitment to robust industrial performance. This combination offers clear business value: faster diagnostics, tighter process control, and traceable data across assets, enabling improved energy management and predictive maintenance. Use cases span compact automation lines, robotics cells and centralized air monitoring, with seamless compatibility for IO-Link masters and standard connector options.

Product Information

Extended Description

M/80/IOL/25C/CC Norgren: Measures compressed air flow rate, pressure, temperature and total volumetric flow consumption | Digital Transmission of parameters via IO-link | Integrated TFT display for easy identification | High accuracy, repeatability and measurement dynamics
Medium
Compressed air, Nitrogen
Operating Temperature
-10 ... 60 °C, 14 ... 140 °F
Operating Pressure
-1 ... 16 bar, -14.5 ... 232 psi
Thread
1" NPT
Flow
3750 l/m, 132.4 scfm
Country of Origin
Germany
Series
M/80
Brand
IMI Norgren
NC-125FS-125MS-5
Connector cable, 5 pin, A-coded, M12, M12, 5m
NC-125FS-125MS-2
Connector cable, 5 pin, A-coded, M12, M12, 2m
NC-125FS-125MS-1
Connector cable, 5 pin, A-coded, M12, M12, 1m
NC-125FS-00000-5
Connector cable, Open end, 5 pin, A-coded, M12, 5m
NC-125FS-125MS-A
Connector cable, 5 pin, A-coded, M12, M12, 0.6m
840014-51KIT
Excelon Plus Quikclamp
840014-52KIT
Excelon Plus Quikclamp with Bracket Assembly
840015-11KIT
Excelon Plus Port Adaptors G1/2
NC-ME-4A4B-12DLA
IO-Link master, EtherNet/IP interface
NC-HB-8A5F-12A0A
IO-Link I/O module, Standard
NC-HA-8A5F-12AAA
IO-Link I/O module, Auxillary power
NC-MP-4A4B-12DLA
IO-Link master, PROFINET interface
Feature: Inline measurement of flow rate, pressure, temperature and total volumetric flow. Business Impact: Real‑time visibility into air consumption enables tighter process control and energy optimization. Application: Ideal for pneumatic lines in manufacturing and packaging environments. The sensor’s compatibility with DN 25 piping supports straightforward retrofits in existing installations. Feature: IO-Link digital transmission with an integrated TFT display. Business Impact: Reduces wiring complexity, speeds commissioning and improves asset identification on the plant floor. Application: Suitable for automated cells where quick diagnostics and traceability matter. Feature: Versatile connectors and mounting options, including 1" NPT threading and Excelon Plus Quikclamp mounting kits. Business Impact: Simplifies installation, minimizes downtime, and accommodates retrofit projects. Application: Fits a range of panel and inline configurations, with mounting accessories (840014-51KIT, 840014-52KIT) for fast setup. Feature: Broad operating range and media compatibility. Business Impact: Extends usable life in harsh factory environments with compressed air and nitrogen media. Application: Air systems in automotive, robotics and process automation. Feature: IO-Link master and I/O module readiness. Business Impact: Enables plug‑and‑play integration with standard IO-Link infrastructure; reduces commissioning time and wiring. Application: Compatible with IO-Link masters (NC‑ME‑4A4B‑12DLA) and I/O modules (NC‑HB‑8A5F‑12A0A) in automated plants. Feature: Robust environmental and mechanical design. Business Impact: Improves uptime with reliable inline sensing and repeatable measurements. Application: Suitable for continuous operation in temperature range -10 to 60 °C and pressure range -1 to 16 bar.

Get a Quick Quote for a Norgren M/80/IOL/25C/CC

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Norgren M/80/IOL/25C/CC? Enquire Now

FAQs

Installation is straightforward with DN 25 inline plumbing and 1" NPT threading. For quick mounting, Excelon Plus Quikclamp kits (840014-51KIT) or with bracket assemblies (840014-52KIT) support fast, secure retention. The device also supports compatible IO-Link masters and standard M12 connector cables, streamlining integration into existing automation footprints.
Key specs include flow capacity of 3750 l/m (132.4 scfm), media compatibility with compressed air and nitrogen, operating temperature -10 to 60 °C, and operating pressure -1 to 16 bar. The sensor delivers inline measurements of flow, pressure, temperature and total volumetric flow with IO-Link digital transmission and an integrated TFT display.
Yes. The inline, IO-Link enabled design provides real‑time data that supports robot cell feedback, line balancing and energy optimization. Its TFT display aids on‑site diagnostics, while the IO-Link interface simplifies integration with automation controllers, making it effective for robotic workcells and centralized air-system monitoring.
The provided data highlights IO-Link compatibility and German origin but does not list specific CE, SIL or IP certifications. For compliance confirmation in a regulated environment, verify with the datasheet (Datasheet PDF) or contact the supplier to confirm any required regulatory certifications before deployment.
The device consolidates multiple measurements into a single inline sensor, reducing hardware counts and wiring. The integrated TFT display speeds troubleshooting, while digital IO-Link transmission improves data reliability and traceability. These factors contribute to faster mean time to repair, reduced energy waste, and a lower total cost of ownership in automated pneumatic networks.