Norgren M/80/IOL/25T/CC Inline flow sensor - IO-Link enabled

Part Number: M/80/IOL/25T/CC
Manufacturer
Norgren
Part number
M/80/IOL/25T/CC

Quick Summary

Inline flow sensor M/80/IOL/25T/CC from Norgren measures flow, pressure, and temperature in compressed air systems. Many installations struggle with opaque readings and manual data collection, causing maintenance delays and energy waste. Designed for industrial reliability, the device supports CE compliance and robust IO-Link data transmission, ensuring reliable digital communication with IO-Link masters. The integrated TFT display enables quick identification and on-site verification, while high accuracy and repeatability support precise monitoring of consumption and efficiency. By pairing DN 25 connections with a wide range of compatible connectors and mounting options, it delivers clear value for line optimization and reduced operating costs. This makes it ideal for OEMs and maintenance teams seeking reliable, data-driven control of compressed air networks.

Product Information

Extended Description

M/80/IOL/25T/CC Norgren: Measures compressed air flow rate, pressure, temperature and total volumetric flow consumption | Digital Transmission of parameters via IO-link | Integrated TFT display for easy identification | High accuracy, repeatability and measurement dynamics
Medium
Compressed air, Nitrogen
Operating Temperature
-10 ... 60 °C, 14 ... 140 °F
Operating Pressure
-1 ... 16 bar, -14.5 ... 232 psi
Thread
R1
Flow
3750 l/m, 132.4 scfm
Country of Origin
Germany
Series
M/80
Brand
IMI Norgren
NC-125FS-125MS-5
Connector cable, 5 pin, A-coded, M12, M12, 5m
NC-125FS-125MS-2
Connector cable, 5 pin, A-coded, M12, M12, 2m
NC-125FS-125MS-1
Connector cable, 5 pin, A-coded, M12, M12, 1m
NC-125FS-00000-5
Connector cable, Open end, 5 pin, A-coded, M12, 5m
NC-125FS-125MS-A
Connector cable, 5 pin, A-coded, M12, M12, 0.6m
840015-11KIT
Excelon Plus Port Adaptors G1/2
840014-52KIT
Excelon Plus Quikclamp with Bracket Assembly
840014-51KIT
Excelon Plus Quikclamp
NC-ME-4A4B-12DLA
IO-Link master, EtherNet/IP interface
NC-HB-8A5F-12A0A
IO-Link I/O module, Standard
NC-HA-8A5F-12AAA
IO-Link I/O module, Auxillary power
NC-MP-4A4B-12DLA
IO-Link master, PROFINET interface
Feature: Measures flow, pressure, temperature, and total volumetric consumption in one inline device. Business impact: Enables centralized monitoring, reduces the need for multiple instruments, and supports energy‑use optimization. Application: suitable for compressed air networks in automotive, packaging, and manufacturing lines. Feature: IO‑Link digital transmission with an onboard TFT display for immediate visibility and diagnostics. Business impact: simplifies wiring, enables remote monitoring, and accelerates commissioning. Application: ideal for centralized control rooms and field installations where quick setup matters. Feature: DN 25 connection with R1 thread and multiple connector options (M12, 5m/2m/1m cables, open end 5m). Business impact: flexible integration into existing manifolds and cabling, reducing modification costs and downtime. Application: retrofit projects and new builds alike. Feature: Mounting options including Excelon Plus Port Adaptors and Quikclamp kits. Business impact: faster, secure installation with fewer tools and less downtime. Application: panel and machine integration in harsh environments. Feature: Media compatibility with compressed air and nitrogen; operating range −10 to 60 °C and −1 to 16 bar. Business impact: robust operation in demanding plants, ensuring steady data in real-world conditions. Application: automotive assembly, process automation, and factory floors. Feature: IO‑Link master compatibility (IO‑Link masters such as NC‑ME‑4A4B‑12DLA and IO‑Link I/O modules). Business impact: streamlined network architecture, scalable diagnostics, and future‑proof expansion. Application: Industry 4.0 data integration and predictive maintenance.

Get a Quick Quote for a Norgren M/80/IOL/25T/CC

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Norgren M/80/IOL/25T/CC? Enquire Now

FAQs

The M/80 supports multiple connector configurations, including NC-125FS variants with 5 pin A-coded M12 cables in lengths of 1m, 2m, and 5m, as well as open-end options. Mounting can be completed with Excelon Plus Port Adaptors or Quikclamp kits (840015-11KIT, 840014-52KIT, 840014-51KIT), enabling fast, secure integration into existing manifolds.
Yes. The device is IO-Link capable and designed to connect with IO-Link masters such as NC-ME-4A4B-12DLA and IO-Link I/O modules NC-HB-8A5F-12A0A and NC-HA-8A5F-12AAA. This enables seamless digital communication, remote diagnostics, and easier network expansion in Industry 4.0 installations.
The sensor operates from −10 to 60 °C (14 to 140 °F) and supports pressures from −1 to 16 bar (−14.5 to 232 psi). It is designed for compressed air and nitrogen, with a DN 25, R1 thread. These specs suit typical plant air networks while maintaining high measurement accuracy.
The integrated TFT display provides at-a-glance identification and quick verification of readings on site. This reduces setup time, speeds troubleshooting, and minimizes downtime when reconfiguring lines or validating measurement targets during commissioning or maintenance.
By delivering real-time data for flow, pressure, temperature, and total consumption via IO-Link, the M/80 enables proactive monitoring and data-driven adjustments. This supports energy savings, meaningful alerts for maintenance, and easier validation of performance improvements across compressed air systems.