Norgren RM1L-NND-NAV Low-Flow Regulator - Cartridge Style

Part Number: RM1L-NND-NAV
Manufacturer
Norgren
Part number
RM1L-NND-NAV

Quick Summary

RM1L-NND-NAV is a precision cartridge-style regulator for miniature pneumatic control in medical and automation applications. Engineers often struggle to find compact regulators that deliver stable output with low pressure drop in space-constrained manifolds. In regulated environments, CE marking is a common requirement, and many systems also demand SIL-capable safety features or IP-rated enclosures to meet compliant operations. The RM1L-NND-NAV’s oxygen-service suitability and cartridge design support faster assembly, reliable performance, and reduced total cost of ownership across medical and industrial lines. This combination delivers tangible value for design engineers and procurement teams alike, while enabling scalable deployments in tightly packaged systems.

Product Information

Extended Description

RM1L-NND-NAV Norgren: Suitable for oxygen service, in medical applications | Excellent flow, pressure drop and hysteresis | Cartridge design for manifold integration
Medium
Compressed air, Gases
Operating Temperature
-5 ... 95 °C, 23 ... 203 °F
Port Size
Cartridge
Adjustment
Adjusting screw
Maximum Inlet Pressure
10 bar
Outlet Pressure Adjustment
0 ... 0.35 bar, 0 ... 5 psi
Relieving / Non Relieving
Non-relieving
Flow
3.3 dm3/sec, 7 scfm
Materials - Body
PPS
Materials - Bonnet
PPS
Materials - Elastomers
FPM
Range
RM1
Brand
IMI Norgren
Feature: Cartridge-style regulator design enables easy manifold integration and compact packaging. Business Impact: Reduces assembly time and space requirements, lowering system cost and improving maintenance access. Application: Used in dense pneumatic manifolds and medical device assemblies where space is at a premium. Long-tail keywords: cartridge regulator, manifold integration, compact regulator. Feature: High flow with low pressure drop and minimal hysteresis. Business Impact: Improves downstream stability, repeatability, and energy efficiency in continuous operation. Application: Medical gas and industrial automation lines requiring precise pressure control. Feature: Temperature range of -5 to 95 °C allows operation in harsh environments. Business Impact: Maintains performance reliability and extends uptime in temperature-varied facilities. Application: Industrial plants and healthcare contexts with varying ambient conditions. Feature: Adjustable outlet pressure from 0 to 0.35 bar (0 to 5 psi). Business Impact: Enables tight regulation and rapid system tuning for specific downstream devices. Application: Pressure-sensitive actuators and instrumentation requiring precise setpoints. Feature: Non-relieving action with PPS body and bonnet, FPM elastomers. Business Impact: Prevents undesired bleed and maintains system pressure, enhancing safety and predictability. Application: Oxygen-service compatible designs and gas handling manifolds. Feature: Flow specification of 3.3 dm3/sec (7 scfm). Business Impact: Sufficient capacity for small-scale, high-precision regulation without oversizing. Application: Micro-regulation stages in medical devices and compact automation equipment. Feature: Material compatibility with PPS body/bonnet and FPM elastomers. Business Impact: Improves chemical and oxygen service compatibility, reducing contamination risk. Application: Medical oxygen applications and gas-controlled systems. Feature: Range RM1 with IMI Norgren branding ensures reliable supply and service support. Business Impact: Simplifies procurement and maximizes uptime with proven distributor networks. Application: OEM assemblies and field maintenance across industries.

Get a Quick Quote for a Norgren RM1L-NND-NAV

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Norgren RM1L-NND-NAV? Enquire Now

FAQs

For cartridge-style manifold integration, ensure the regulator is mounted in a location with adequate clearance for the cartridge insert and adjustment screw access. Use compatible PPS body hardware and correct elastomer seals (FPM) to maintain gas compatibility. Verify inlet pressure does not exceed 10 bar and that downstream components tolerate 0–0.35 bar outlet pressures. Proper torque on mounting fittings helps prevent leaks and ensures consistent regulation.
The unit is designed for compressed air and gases and is suitable for oxygen service in medical and related applications. Ensure all downstream components are compatible with the chosen gas medium and that system cleanliness is maintained to prevent contaminants from affecting regulation. Material choices—PPS for body and bonnet, FPM elastomers—support chemical compatibility in typical gas handling environments.
Outlet pressure is adjustable from 0 to 0.35 bar (0 to 5 psi) using the adjusting screw. The cartridge-style design minimizes hysteresis for repeatable setpoints, and the non-relieving configuration helps maintain downstream pressure under steady-state conditions. This makes the regulator well-suited for sensitive actuators and instrumentation requiring stable pressure control.
The RM1L-NND-NAV features PPS bodies and bonnet, providing chemical resistance and structural stability across typical pneumatic and gas-handling environments. FPM elastomers offer good resistance to fuels and many chemicals, improving long-term sealing performance. These material choices support oxygen service and help minimize contamination risk in medical and industrial deployments.
Its cartridge design simplifies installation and maintenance, reducing assembly time and field downtime. The combination of compact size, stable outlet pressure, and robust materials lowers the risk of leaks and regulator failures, contributing to longer service intervals and fewer warranty issues. Overall, it supports faster time-to-market and lower lifecycle costs for OEMs and maintenance teams.