Rittal 5301285 Partition - Integrated Sealing Profile for VX IT
Part Number: 5301285
Quick Summary
Rittal 5301285 Partition enables retrofitting for VX IT bayed enclosures, enabling retrospective installation or dismantling with an integrated sealing profile. Without a retrofit solution, changing layouts risks compromised seals and complicates climate control or extinguisher-gas compliance. This accessory aligns with ETIM EC002525 and ECLASS 27189234 classifications to ensure consistent procurement across VX IT ecosystems. It also supports climate-control sealing and retrofit-from-inside-or-outside installation, delivering faster projects and reduced downtime. Designed for retrofit success in both field and factory environments, it helps engineers meet schedules and protect critical climate and gas safety requirements. This combination accelerates acceptance testing and procurement cycles.
Product Information
Extended Description
5301285 Rittal: For retrospective installation/dismantling of bayed enclosures. The integrated sealing profile supports enclosure sealing for climate control or for applications with extinguisher gas. It may be fitted from the outside prior to baying the enclosure, or from the inside after baying the enclosure. As the partition is located inside the frame structure, it may be retrofitted at any time. There are no specific required baying distances between the enclosures.
Article number
VX_IT 5301.285
Product description
For retrospective installation/dismantling of bayed enclosures. The integrated sealing profile supports enclosure sealing for climate control or for applications with extinguisher gas. It may be fitted from the outside prior to baying the enclosure, or from the inside after baying the enclosure. As the partition is located inside the frame structure, it may be retrofitted at any time. There are no specific required baying distances between the enclosures.
Material
Sheet steel, zinc-plated
Supply includes
2 partitioning plates | 4 cover caps | Punched rail | Seal | Assembly parts
Assembly instruction
Assembly/removal only supported for enclosures without interior installation.
Packs of
1 pc(s).
Customs tariff number
94039910
EAN
4028177954861
ETIM 9
EC002525
ECLASS 8.0
27189234
Feature integrated sealing profile for climate control and extinguisher-gas applications → Business impact: maintains enclosure integrity during retrofits and reduces leak risk, supporting compliant climate control and safety systems in VX IT bayed enclosures. Application: ideal for retrofit projects in data centers and industrial cabinets where gas suppression or precise temperature control is mandatory. Feature sheet steel, zinc-plated construction → Business impact: robust, corrosion-resistant hardware that extends service life in harsh environments, lowering maintenance costs. Application: suitable for outdoor-fed or humid plant rooms where enclosure longevity matters. Feature supply includes 2 partitioning plates, 4 cover caps, punched rail, seal, and assembly parts → Business impact: complete retrofit kit minimizes vendor coordination and lead times, reducing project duration. Application: streamlined procurement for panel builders and system integrators. Feature installation flexibility (outside before baying or inside after baying) → Business impact: minimizes downtime and logistics complexity, enabling fast reconfiguration of rack layouts. Application: adaptable to evolving plant layouts without disassembly. Feature assembly/removal is supported for enclosures without interior installation → Business impact: clear installation boundaries prevent improper retrofitting and ensure safe, compliant retrofits. Application: proper fitment in VX IT configurations to preserve warranty and performance. Feature no specific baying distance requirement → Business impact: simplifies planning, lowers risk when expanding or reconfiguring bays. Application: scalable across multi-unit VX IT rows. Feature small-pack option (1 pc) → Business impact: predictable inventory and cost control during upgrades. Application: efficient stocking for frequent maintenance cycles.
Get a Quick Quote for a Rittal 5301285
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Rittal 5301285?
Enquire Now
FAQs
The partition can be fitted from the outside prior to baying or from the inside after baying, providing flexible retrofit options. Assembly/removal is supported only for enclosures without interior installation. Practically, you remove or loosen existing enclosure elements, place the partitioning plates inside the frame, secure with the supplied hardware and seal, then reassemble. The kit includes all necessary parts for a complete retrofit, reducing field coordination and downtime.
Key specs include material: sheet steel, zinc-plated; supply: 2 partitioning plates, 4 cover caps, punched rail, seal, assembly parts; packs: 1 pc; customs tariff: 94039910; EAN: 4028177954861; ETIM 9: EC002525; ECLASS 8.0: 27189234. It is designed specifically for retrospective installation/dismantling of bayed VX IT enclosures and supports climate-control sealing and gas-safety applications.
Yes. The integrated sealing profile is designed to maintain enclosure sealing for climate-control requirements and for applications involving extinguisher gas, ensuring continued performance after retrofits. The inside-frame placement allows retrofits without compromising the frame integrity, preserving environmental conditions inside the enclosure.
The VX_IT 5301.285 partition aligns with ETIM 9 EC002525 and ECLASS 8.0 27189234 classifications, which standardize data/product attributes for procurement and integration with VX IT ecosystems. These classifications help ensure interoperability with other VX IT components and consistent cataloging across supplier databases.
The retrofit kit minimizes downtime by enabling quick outside- or inside-mounted installation, eliminates the need for full enclosure replacement, and consolidates hardware into a single package. By preserving seals and climate-control integrity, it reduces post-installation commissioning time and supports long-term cost savings through extended enclosure life and easier future reconfigurations.