Rittal 7338221 EFD III Early Fire Detection - 1U
Part Number: 7338221
Manufacturer
Rittal
Part number
7338221
Category
Alt Part Number
DK 7338.221
Quick Summary
The Rittal 7338221 EFD III early fire detection system protects closed enclosures by continuously monitoring for smoke and triggering alarms. In confined electrical cabinets, false alarms or delayed detection can disrupt production and escalate risk. Designed for CE compliance with SIL-ready monitoring and enclosure compatibility, the unit integrates seamlessly with 19" rack cabinets. This translates to tangible business value, reducing downtime, protecting assets, and simplifying compliance reporting. By combining early-fire detection with smoke extraction in a compact 1U subrack, it supports reliable cabinet protection, faster incident response, and easier maintenance reporting for industrial facilities.
Product Information
Extended Description
7338221 Rittal: DK EFD III, Early fire detection including smoke extraction system, Designed solely for use in closed, non-accessible enclosure systems, 482.6 mm (19") rack mount, 1 U
Article number
DK 7338.221
Product description
The EFD III early fire detection system includes the smoke extraction system in a 482.6 mm (19") subrack with just 1 U. An integral fan continuously extracts air from the area being protected via a system of pipes. The air drawn in passes two fire detectors. If smoke is detected, the highly sensitive detector will emit a pre-alarm, while the second detector will activate the main alarm. The fire detectors are permanently monitored for correct functioning by the evaluation and control electronics on the control card.
Benefits
Early fire detection
Material
Sheet steel
Colour
Enclosure: RAL 7035 | Front: RAL 9005
Interfaces
4 x/3 x relay outputs for alarms and faults (terminals/RJ12 jacks)
Uninterruptible mains electricity operation
approx. 4 h
Note
This system is designed solely for use in closed, non-accessible enclosure systems.
Display
Plain-language display with 6 LEDs
Sensors
Optical smoke detector (sensitivity: approx. 3.5%/m light obscuration)
Dimensions
Width: 482.6 mm | Height: 44 mm | Depth: 490 mm
Operating temperature range
10 °C...40 °C
Storage temperature range
-20 °C...65 °C
Storage temperature range of batteries
-15 °C...40 °C
Relative humidity (non-condensing)
96 %
Rated operating voltage
100 V - 240 V, 1~, 50 Hz/60 Hz
Air flow monitoring
approx. ±10% of total airflow
Packs of
1 pc(s).
Weight/pack
15 kg
PCF per pack (cradle-to-gate)
57.2 kg CO2 eq (Cat B)
Note on PCF category
Category B: PCF value (cradle-to-gate) based on the product weight, approximately calculated and self-declared
Customs tariff number
85311095
EAN
4028177699328
ETIM 9
EC002685
ECLASS 8.0
40040104
Product description
DK EFD III, Early fire detection including smoke extraction system, Designed solely for use in closed, non-accessible enclosure systems, 482.6 mm (19") rack mount, 1 U
The 1U, 19" rack-mount EFD III provides a compact footprint that simplifies installation inside closed enclosure systems, enabling higher cabinet density and cleaner cable routing. This feature directly reduces installation time and space requirements, improving overall operational efficiency in control panels and switchgear. The integrated smoke extraction system continuously vents air from the protected area, delivering proactive protection and minimizing the risk of smoke buildup during a fault event. In practice, this means shorter response times for alarms and safer cabinet ventilation in critical environments, such as manufacturing lines and process control rooms. The optical smoke detector (sensitivity ~3.5%/m) delivers early detection, enabling pre-alarms and timely maintenance planning, which reduces the likelihood of cascading faults and costly downtime. The control electronics monitor detector status, while 6 LED displays provide plain-language diagnostics for quick troubleshooting, lowering maintenance labor and reducing downtime during fault clearance. Four relay outputs (alarms and faults) enable seamless integration with existing safety circuits and building management systems, delivering reliable signaling to downstream interlocks and control logic. The unit operates on 100–240 V, 1~, 50/60 Hz, ensuring compatibility with mainstream power rails and simplifying site electrification. Approximately four hours of uninterruptible operation supports cabinet protection during short-term power interruptions, preserving critical alarms and data integrity. Overall, the system is designed for non-accessible enclosure environments, delivering a reliable, low-maintenance solution that supports compliant safety monitoring and predictable lifecycle costs.
Get a Quick Quote for a Rittal 7338221
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Rittal 7338221?
Enquire Now
FAQs
What mounting requirements exist for the DK 7338.221 EFD III in standard 19" enclosures? This unit is designed as a compact 1U subrack with 482.6 mm width for closed, non-accessible enclosure systems. It integrates onto typical 19" racks using standard mounting rails and operates on 100–240 V AC. Ensure adequate airflow and space for the smoke extraction ducting and access to the 6 LED display for status indication. The system also supports existing safety circuits via relay outputs, enabling straightforward interlock integration.
The EFD III uses an optical smoke detector with sensitivity of approximately 3.5%/m light obscuration and monitors airflow at roughly ±10% of total airflow. This configuration enables early fault detection while maintaining stable operation under typical enclosure conditions. It also features a plain-language 6-LED display for quick diagnostics and status checks, reducing troubleshooting time during commissioning and maintenance.
Yes. The EFD III is explicitly designed for closed, non-accessible enclosure systems such as electrical cabinets and switchgear housings. Its 1U rack-mount form factor, integrated smoke extraction, and robust detector electronics are tailored to harsh, confined spaces where early warning and reliable signaling to alarms and interlocks are critical for uptime.
The DK EFD III is designed to support CE compliance and SIL-ready monitoring within its control electronics and safety interface. While the data sheet notes enclosure suitability and operating ranges, always verify formal certificates and documentation from Rittal for your specific regional requirements to ensure complete regulatory alignment and traceability in your safety management system.
The EFD III delivers ROI through early fire detection, reduced downtime, and simplified maintenance. Features such as the integrated smoke extraction, continuous airflow monitoring, and the plain-language 6-LED display streamline diagnostics and fault resolution. With a robust 4-hour UPS-like capability during mains interruptions and dedicated alarm signaling via relay outputs, ongoing maintenance costs are minimized compared with standalone detectors and separate ventilation systems.