Rittal 7857972 RM Security room - ECB‑S EN 1047‑2 certified
Part Number: 7857972
Manufacturer
Rittal
Part number
7857972
Category
Alt Part Number
RM 7857.972
Quick Summary
Rittal 7857972 RM Security room protects data centres by delivering modular protection for IT and infrastructure. Many data centers struggle with unauthorized access, fire, and environmental threats. Key certifications include ECB‑S EN 1047‑2 for extreme temperature and humidity endurance, RC 3 unauthorised access testing to EN 1627/1630, and IP 5X dust-tightness verified by system tests. This modular, room-within-a-room solution helps reduce risk, speeds deployment, and supports scalable protection for growing data center needs.
Product Information
Extended Description
7857972 Rittal: RM Security room, High Availability room (HVR)
Article number
RM 7857.972
Design
High Availability room
Product description
The basic protection room - an optimum, modular room-within-a-room solution for protecting IT/infrastructure components. The High Availability room - certified maximum physical protection for data centres and IT system locations.
Note
Tested products are tested as a complete construction. This comprises the cellular structure and installation modules such as doors, cable shields or ventilation units. By contrast, component testing only refers to individual parts.
Corrosive fire gases
Protection from acrid gases to DIN 18 095
Falling debris
Shock test as system test, 3 shocks of 200 kg from 1.5 m after 45 minutes flame impingement time
Dust-tightness
IP 5x as system testing to EN 60 529, for the cellular structure and its built-in modules
EMC protection
Protection against high-frequency irradiation and radiation, verified by tests on comparable components by TU Aachen
Fire protection
ECB·S certifications to EN 1047-2, 50 K temperature increase and 85% rel. humidity up to 24 hours (reheating period), 60 minutes flame impingement time
Unauthorised access
RC 3 as system test to EN 1627/1630, for the cellular structure and its built-in modules, such as doors
Water
Standing water, 72 hours, 40 cm, maximum 20 drops
Explosion protection
Detonation test as system testing of 200 kg TNT from 40 m
Packs of
1 pc(s).
EAN
4028177689350
ETIM 9
EC002499
ECLASS 8.0
27180207
Product description
RM Security room, High Availability room (HVR)
Feature: Modular room-within-a-room construction. This approach creates a dedicated, shielded enclosure around IT components, improving physical security and resilience against environmental threats. Application: ideal for data centers undergoing expansion or retrofit, where rapid, risk-controlled integration is essential. The business impact is reduced downtime and a smoother rollout of additional capacity. Feature: ECB‑S EN 1047‑2 certification and high temperature/humidity endurance. This ensures proven protection against fire and environmental stress, increasing uptime and asset longevity. Application: data center rooms requiring strict fire protection and stable climate conditions. Feature: RC 3 unauthorised access protection tested to EN 1627/1630. Improves security posture and regulatory compliance, reducing breach risk. Application: secure IT halls and server rooms with reinforced access controls. Feature: IP 5X dust-tightness and water resilience (72 hours, 40 cm). Supports reliable operation in dusty or damp environments, lowering maintenance costs. Application: installations near service corridors or variable external conditions. Feature: EMC protection validated by TU Aachen tests. Minimizes EMI risks and ensures compatibility with sensitive IT equipment. Application: data centers with dense electronic equipment and EMI-sensitive devices. Feature: Full system testing of cellular structure and installation modules (doors, cable shields, ventilation units). Guarantees integrated performance, reducing on-site integration time and surprises. Application: procurement of a complete protection package for rapid, compliant deployment.
Get a Quick Quote for a Rittal 7857972
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Rittal 7857972?
Enquire Now
FAQs
Installation begins with site verification of space and structural readiness, followed by delivery of the modular room components. The process includes mounting the cellular structure, attaching doors, installing cable shields and ventilation units, and integrating power and data feeds. The design supports rapid, risk-controlled deployment with clear alignment to existing IT racks and infrastructure.
ECB‑S EN 1047‑2 certification confirms the protective enclosure withstands critical fire and thermal events within defined limits, maintaining operational integrity of IT hardware. In practice this means improved uptime during incidents, reduced heat exposure to equipment, and predictable performance during demanding load conditions, which translates to lower risk of data loss and shorter recovery times.
Yes. The design emphasizes dust-tightness (IP 5X) and environmental resilience, including capabilities to withstand standing water for extended periods and controlled fire exposure. This makes it well-suited for outdoor-adjacent facilities, retrofit sites, or spaces with fluctuating environmental conditions, while maintaining IT reliability.
RC 3 unauthorised access testing verifies the robustness of doors and enclosure components against forced entry. It aligns with EN 1627/1630 performance classes, ensuring a higher level of physical security for server rooms and data halls, helping compliance with corporate and regulatory security requirements.
By delivering a complete, tested protection package (cellular structure, doors, cable shields, ventilation), the solution reduces installation risk, accelerates time-to-operational readiness, and lowers maintenance complexity. Its robust protection lowers downtime costs, asset damage risk, and future expansion costs, improving long-term ROI for data center protection.