Rittal DK 7979.402 PDU for IT racks - EN 62368-1

Part Number: 7979402
Manufacturer
Rittal
Part number
7979402
Alt Part Number
DK 7979.402

Quick Summary

Rittal DK PDU delivers energy-measured, per-output power distribution for IT racks and servers. This design addresses the common challenge of opaque power consumption, which hampers cost control and capacity planning. The unit complies with EMC Directive 2014/30/EU and EN 62368-1 safety standards, reinforcing reliability in networked environments, while its robust 230 V operation and 16 A per-infeed rating meet modern server room demands. By integrating a web server interface, PoE-powered management, and a rotatable display, it simplifies remote monitoring and rapid fault isolation. Business value comes from improved energy efficiency, reduced downtime, and streamlined asset management through per-outlet measurement and secure communications.

Product Information

Extended Description

7979402 Rittal: DK PDU managed, high-end power distribution incl. energy measurement, switching and monitoring functions per output slot, with network interface and display, WHD: 450x44x144 mm; IEC 60 320: 6x C13
Article number
DK 7979.402
Design
482.6 mm (19") version
Product description
High-end power distribution in a compact design for IT network and server racks. Depending on the design, they come with an extensive range of management functions for energy measurement and monitoring.
Benefits
For vertical mounting, it may be attached in the zero-U space of the Rittal VX IT or TS IT rack with no need for tools
Technical specifications
Display/controller unit in the PDU enclosure rotatable through 180° and replaceable
Material
Aluminium section, black anodised | Slots: Plastic
Supply includes
Assembly parts | No connection cable, to be provided by the customer.
Options
CMC III CAN bus sensors may be connected for ambient monitoring, max. 16 sensors
Measurement functions, description
Emergency power supply to PDU web server via PoE, sequential disconnection of the outputs
Dimensions
Height: 44 mm | Depth: 144 mm | Length: 450 mm
No. of sockets and type
6 x C13
Sockets
6 x C 13
Rated operating voltage
230 V (AC)
Rated current (max.)
16 A
Power consumption
3.7 kW
Infeeds
Qty.: 1 | Phases per infeed: 1~
Type of electrical connection
IEC C20
Interfaces
Fully redundant Ethernet interface 10/100/1000 Mbit/s (2x RJ45, 1x with PoE)
Directives
EMC Directive 2014/30/EU
Standards
EN 62368-1
Protocols
Web server (HTTP, HTTPS, SSL) SSH, Telnet, NTP
Operating temperature range
5 °C...50 °C
Ambient humidity (non-condensing)
10...95 %
Storage temperature range
-20 °C...70 °C
To fit
Enclosure type: VX IT enclosure frame: ≥ 800 mm | Enclosure type: VX IT 19" mounting angles: ≥ 800 mm
Packs of
1 pc(s).
Weight/pack
3 kg
Customs tariff number
85366990
EAN
4028177948044
ETIM 9
EC002762
ETIM 8
EC002762
ECLASS 8.0
27142604
Product description
DK PDU managed, high-end power distribution incl. energy measurement, switching and monitoring functions per output slot, with network interface and display, WHD: 450x44x144 mm; IEC 60 320: 6x C13
Energy measurement per output slot enables precise cost allocation and load trending, reducing waste and optimizing capacity planning. Business impact: lower energy bills and better budgeting for IT loads. Application: data centers and enterprise server rooms needing per-outlet visibility. The fully redundant Ethernet interface with PoE supports reliable, remote monitoring and seamless integration into existing network architectures. This translates to faster fault detection and simpler maintenance, lowering mean time to repair. Business impact: higher uptime and reduced service windows. Application: rack-scale deployments with centralized management. The compact 19" design (450x44x144 mm) and zero-U mounting option allow vertical installation in VX IT racks, saving valuable rack space. Business impact: denser computing layouts and easier cabling. Application: VX IT and TS IT rack ecosystems. The rotatable display/controller unit (180°) is serviceable and replaceable, reducing downtime during maintenance. Business impact: improved lifecycle management and lower spare parts costs. Application: fielded IT environments requiring easy, tool-free servicing. The PDU supports C13 sockets (6x) with 230 V, 16 A rating and IEC C20 inlet, ensuring compatibility with standard IT power architectures. Business impact: straightforward sourcing and predictable performance. Application: new or upgrade IT rack builds. Optional CMC III CAN bus sensors enable ambient monitoring, extending visibility to environment conditions. Business impact: proactive environmental control and compliance support. Application: data centers with strict ambient monitoring requirements. Overall, the DK PDU aligns with IT managers’ needs for scalable, compliant, and monitorable power distribution.

Get a Quick Quote for a Rittal 7979402

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Rittal 7979402? Enquire Now

FAQs

The DK 7979.402 PDU is designed for VX IT enclosures and 19" mounting. It can be attached in the zero-U space of compatible VX IT frames, saving rack space and simplifying cabling. You will need a customer-supplied IEC C20 inlet cable; the PDU itself ships as a single unit with six C13 outlets and a rotatable display for easy setup and monitoring.
This PDU complies with the EMC Directive 2014/30/EU and EN 62368-1 safety standards, ensuring regulatory compliance and reliable performance in networked IT environments. It also supports standard IT power infrastructure with a 230 V supply and a 16 A maximum current rating, aligning with common rack architectures.
Yes. The DK PDU provides energy measurement and monitoring per output slot, enabling precise usage reporting and cost allocation. It is designed to integrate with a Web server interface, allowing remote access to per-outlet data and fault indicators for proactive management.
Compatibility is built into the design for VX IT enclosure frames and 19" mounting. The unit supports vertical mounting in zero-U spaces and includes mounting provisions for VX IT frames with adjustable enclosure width, offering flexibility for space-constrained data centers and edge deployments.
The per-outlet energy visibility, remote management via a secured interface, and automated power sequencing translate into reduced energy waste, faster fault isolation, and lower operational downtime. Combined with regulatory compliance and lifecycle efficiency, this can shorten payback periods and improve total cost of ownership for IT power infrastructure.