Rittal 7979813 PDU UK Basic - EN 62368-1, 16x BS 1363
Part Number: 7979813
Manufacturer
Rittal
Part number
7979813
Category
Alt Part Number
DK 7979.813
Quick Summary
Rittal DK PDU UK basic provides compact power distribution for IT racks in data centers. Engineers often battle cramped cabling, limited expandability, and the challenge of achieving reliable energy visibility in dense server cabinets. It carries CE conformity under the EMC Directive 2014/30/EU and EN 62368-1 safety standards, ensuring compliant installations across EU and UK facilities. With a tool-free VX IT divider kit, a 3 m UK connection cable, and energy monitoring options, it delivers scalable, observable power for IT resilience and lower operating costs.
Product Information
Extended Description
7979813 Rittal: DK PDU UK basic, compact basic power distribution, WLD: 44x1095x70 mm, 16x BS 1363, 230 V, 1~, 13 A
Article number
DK 7979.813
Product description
High-end power distribution in a compact design for IT network and server racks. Depending on the design, they come with an extensive range of management functions for energy measurement and monitoring.
Benefits
Tool-free divider kit for VX IT
Technical specifications
Colour coding of phases and fuse circuits (L1=pink, L2=black, L3=white)
Material
Aluminium section, black anodised | Slots: Plastic
Supply includes
Assembly parts
Options
Type 3 overvoltage protection with interchangeable arresters while operational, with status monitoring, suitable for integration into PDU enclosure | Type 3 overvoltage protection with interchangeable arresters while operational, with status monitoring, suitable for integration into PDU enclosure |
Dimensions
Width: 44 mm | Depth: 70 mm | Length: 1,095 mm
No. of sockets and type
16 x BS 1363
Sockets
16 x BS 1363
Rated current (max.)
13 A
Power consumption
3 kW
Infeeds
Qty.: 1 | Phases per infeed: 1~
Length of connection cable
3 m
Type of electrical connection
UK
Directives
EMC Directive 2014/30/EU
Standards
EN 62368-1
Operating temperature range
5 °C...50 °C
Ambient humidity (non-condensing)
10...95 %
Storage temperature range
-25 °C...70 °C
To fit
Enclosure type: VX IT enclosure frame: ≥ 1,200 mm | Enclosure type: VX IT 19" mounting angles: ≥ 1,800 mm | Enclosure type: TX CableNet: ≥ 1,200 mm
Packs of
1 pc(s).
Customs tariff number
85369095
EAN
4028177948594
ETIM 9
EC000330
ETIM 8
EC002762
ECLASS 8.0
27142604
Product description
DK PDU UK basic, compact basic power distribution, WLD: 44x1095x70 mm, 16x BS 1363, 230 V, 1~, 13 A
Feature: Compact, space-efficient design with dimensions 44x1095x70 mm and 16x BS 1363 sockets. Benefit: Maximizes rack density and reduces cabinet footprint, simplifying data center cable management. Application: IT server racks and data centers seeking efficient power distribution. Feature: Robust aluminium section, black anodised with plastic slots. Benefit: Durable, lightweight construction that withstands data-center conditions and aids installation in VX IT frames. Application: Mounting in VX IT enclosure frames for reliable long-term operation. Feature: Energy measurement and monitoring options. Benefit: Enhanced visibility into power usage, enabling cost control and efficiency improvements. Application: IT networks and server racks requiring proactive energy management. Feature: Type 3 overvoltage protection with interchangeable arresters (while operational) and status monitoring. Benefit: Increased protection for critical IT gear and simplified maintenance with real-time status. Application: Data centers needing robust surge protection integrated into the PDU enclosure. Feature: Color coding of phases and fuse circuits (L1=pink, L2=black, L3=white). Benefit: Faster fault isolation and safer maintenance with reduced human error. Application: Routine IT cabinet servicing and lifecycle management. Feature: Infeeds 1, 1~, length of connection cable 3 m, UK connection. Benefit: Simple, plug-and-play installation with clear UK power compatibility. Application: Straightforward deployment in UK facilities and VX IT enclosures. Feature: Operating conditions and standards. Benefit: Reliable operation across 5 °C to 50 °C and 10–95% humidity, with EN 62368-1 and EMC compliance for regulated environments. Application: Data centers operating under varied ambient conditions.
Get a Quick Quote for a Rittal 7979813
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Rittal 7979813?
Enquire Now
FAQs
To install the DK PDU UK basic in a VX IT enclosure, place the unit inside the frame and secure it with compatible mounting hardware. Use the tool-free divider kit to partition power paths and keep cables tidy. It ships with assembly parts and a 3 m UK connection cable; dimensions are 44x1095x70 mm and it operates at 230 V, 1~, 13 A.
Model 7979813 provides 16x BS 1363 sockets at 230 V, 1~, with a maximum current of 13 A and a total power rating of 3 kW. It uses a 3 m UK connection cable and a single infeed. Overall dimensions are 44 mm wide, 70 mm deep, and 1,095 mm long, suitable for UK installations.
Yes. The PDU complies with CE conformity under the EMC Directive 2014/30/EU and follows EN 62368-1 safety standards, supporting regulatory compliance in EU and UK facilities. This reduces audit risk and simplifies deployment in regulated environments, while the color-coded phases aid maintenance safety.
The DK PDU UK basic offers an extensive range of management functions for energy measurement and monitoring, enabling visibility into per-socket or per-phase power usage. This supports IT budgeting, power optimization, and ongoing efficiency improvements for data centers and server rooms.
Its compact footprint, rugged aluminium body, and VX IT enclosure compatibility minimize space usage while improving airflow and cable management. The tool-free VX IT divider kit accelerates setup, and color-coded L1/L2/L3 wiring reduces maintenance risk, all contributing to faster deployments and higher IT uptime in busy data centers.