Rittal 9640261 SV Maxi-PLS busbar - 1,354 mm²
Part Number: 9640261
Manufacturer
Rittal
Part number
9640261
Category
Alt Part Number
SV 9640.261
Quick Summary
Rittal SV Maxi-PLS busbar delivers high-conductivity power distribution for switchgear and control panels. Engineers often wrestle with waste, mismatched lengths, and on-site cutting delays that slow commissioning. This part aligns with ETIM EC001522 and ECLASS 27370303 classifications to ensure interoperability across systems and suppliers. For scalable, modular rack installations, Maxi-PLS 2000 offers predictable copper weight and standard 891 mm length, while the E-Cu material delivers low resistance and durable performance. The ability to cut to length helps minimize waste and inventory, while compatible fittings and a 1,354 mm² cross-section support robust fault tolerance. This translates to faster installs, improved reliability, and lower lifecycle costs in demanding industrial environments.
Product Information
Extended Description
9640261 Rittal: SV Maxi-PLS busbar E-Cu, L: 891 mm, Maxi-PLS 2000
Article number
SV 9640.261
Product description
For assembling cable connection systems.
Material
E-Cu
Cross-section
1,354 mm²
Length
891 mm
Note
May be cut individually to required length
To fit
Width: = 1,000 mm
Packs of
1 pc(s).
Weight/pack
11.8 kg
Copper weight (kg per piece)
10.74
Customs tariff number
74071000
EAN
4028177569416
ETIM 9
EC001522
ECLASS 8.0
27370303
Product description
SV Maxi-PLS busbar E-Cu, L: 891 mm, Maxi-PLS 2000
Material: E-Cu provides high electrical conductivity and robust mechanical strength, which translates to lower I²R losses and improved thermal stability in dense cabinet layouts. Business impact: reduced energy waste and cooler operation in continuous-duty applications. Application: ideal for cable connection systems in power distribution assemblies where reliability is critical. Cross-section: 1,354 mm² enables higher current carrying capacity for Maxi-PLS 2000 configurations. Business impact: supports increased load demands without enlarging panel footprint. Application: suitable for high-power control panels in manufacturing lines. Length: 891 mm offers a precise fit for widths up to 1,000 mm. Business impact: minimizes unused space and simplifies mounting. Application: perfect for standardized rack installations in switchgear housings. May be cut to length: this field-cut capability reduces stock variety and waste. Business impact: lowers inventory costs and accelerates on-site tailoring. Application: common in modular power distribution setups. Copper weight per piece: 10.74 kg, weight per pack 11.8 kg. Business impact: predictable shipment and handling during installation. Application: practical for controlled cabinet assembly and logistics planning. ETIM 9 EC001522 and ECLASS 8.0 27370303 alignment: ensures seamless data exchange with procurement and digital catalogs. Business impact: improves interoperability and reduces miscommunication. Application: supports automated BOM generation and supplier integration in industrial environments.
Get a Quick Quote for a Rittal 9640261
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Rittal 9640261?
Enquire Now
FAQs
SV 9640.261 is designed as an E-Cu Maxi-PLS busbar compatible with Maxi-PLS 2000 configurations. It supports a 1,354 mm² cross-section and an 891 mm length, enabling seamless integration into existing Maxi-PLS based switchgear and panel layouts. This compatibility minimizes adaptation work and reduces installation risk during system upgrades.
With an 891 mm length, the busbar fits typical 1,000 mm wide cabinet enclosures, simplifying routing and stacking in control panels. Consider alignment with mounting planes, cabinet clearances, and end-connectors compatible with E-Cu bars. The field-cut capability can further tailor length on-site, reducing waste and ensuring precise fit without compromising electrical continuity.
The 1,354 mm² cross-section provides substantial current-carrying capacity for demanding applications within Maxi-PLS 2000 configurations. While exact ratings depend on installation conditions, the E-Cu material ensures low resistive losses and favorable thermal behavior, supporting stable operation in high-density power distribution cabinets and switchgear assemblies.
The SV Maxi-PLS busbar aligns with ETIM 9 EC001522 and ECLASS 8.0 27370303 classifications, facilitating interoperability across procurement platforms and downstream systems. While explicit CE or IP ratings are not listed in the data, this alignment supports standardized data exchange and compatibility in diverse industrial environments.
Using E-Cu Maxi-PLS busbars offers lower resistance and durable performance, translating to energy savings and reduced thermal management needs. Field-cut capability reduces inventory and on-site waste, speeding commissioning and lowering labor costs. Over the lifecycle, reliable copper busbars help minimize maintenance interruptions and service outages in critical production lines.