003H6586
Part Number: 003H6586
Product Information
Extended Description
003H6586 Danfoss: AVPBT-F PN25 15/2,5 0,5 thread return
Gross weight
3.116 Kilogram
Net weight
3.116 Kilogram
Volume
9.59 Liter
EAN
5702421541050
Application
District Heating
Cavitation factor
0.6
Cavitation factor 100%
0.41
Cavitation factor 25%
0.69
Cavitation factor 50%
0.62
Cavitation factor 75%
0.6
China RoHS compliance
Out of scope
Connection size
G 3/4 A
Connection types
External Thread
Contain batteries
No
Description
AVPBT-F PN25 15/2,5 0,5 thread return
Diameter [mm]
15 mm
Differential pressure range [bar] [Max]
20 bar
Differential pressure setting [bar] [Max]
0.5 bar
Differential pressure setting [bar] [Min]
0.5 bar
dPb virtual
0.2
EU RoHS compliance
Yes with exemptions
Flow control
No
Flow limitation
Yes
Flow rate [m³/h]
1.4 m³/h
Flow rate [m³/h] [Max]
1.6 m³/h
Flow rate [m³/h] [Min]
0.07 m³/h
Function
Diff. press. and temp. contr. with flow limi.
Function VSP - P
Yes
Function VSP - Q
Yes
Function VSP - T
No
Kvs values [m³/h]
2.5 m³/h
Leakage rate [% Kvs]
0.02
Media pH [Max]
10
Media pH [Min]
7
Media temperature [°C] [Max]
150 °C
Media temperature [°C] [Min]
2 °C
Medium alternative
Glycolic water up to 30%
Mounting version
Return
Number of ports
2
Permissible media
District heating/cooling circulation water
PN alternative VSP
16
Pressure class
PN 25
Pressure controller
Differential pressure controller
Pressure nominal [bar]
25 bar
Product group
Pressure flow controllers
REACH Candidate List substances
Lead (CAS no. 7439-92-1)
Setting Type
Fixed
Stem position
Normally open
Type
AVPBT-F
UK RoHS compliance
Out of scope
Valve body material
Red bronze CuSn5ZnPb (Rg5)
Valve cone DP material
Dezincing free brass CuZn36Pb2As
Valve size
DN 15
How to avoid pressure oscillations in district heating systems
Hydraulic balance in a district cooling system
Hydraulic balance in a district heating system
Improved temperature control and hydronic balance for your benefit
Save energy with efficient and safe steam distribution
Track down and solve any hydronic imbalance with self acting controls
Hydraulic balancing reduces refrigerations costs significantly
AVPB/AVPB-F/AVPBT/AVPBT-F
Danfoss EU 230530EN0858104.05
Actuators pressure flow and temperature
BV UKCA-0041-PESR-H-DAF 001-22-FBR
Danfoss UK 230612EN0856102.02
Self-acting differential pressure and temperature controller with flow limitation type AVPBT-F with protection cap
Self-acting differential pressure and temperature controller with flow limitation type AVPBT-F with protection cap