132H2909
Part Number: 132H2909
Product Information
Extended Description
132H2909 Danfoss: Frequency converterVACON0100-3L-0460-5-ED-FLOW+IP54+FL03+DLNL+CAPT+CAPS+CICO+CIFD+GNULVACON 100 FLOW380-500 Vac, 460 Amp, IP54/NEMA12Graphical Keypad MK01C3 Commercial&Industry EnvironB Slot: F3,3 Relay boardC Slot: No boardD Slot: No boardFieldbus: Std protocol,Modbus,N2,BacNetManual: DutchFrame 10E Slot: No boardOther options according to Model code
Gross weight
376.95 kg
Net weight
359 kg
Volume
0 l
EAN
5714853317165
Product View (Switch)
GLBL : Global (Standard)
Segment
-FLOW : VACON 100 FLOW
Region Code
-R00 : R00 International
Mains voltage
-5 : 380-500 Vac
Current rating
-0460 : 460 Amp
Installation options
-ED : ED Enclosed Drive
Enclosure
+IP54 : IP54/NEMA12
Control panel
+HMGR : Graphical Keypad MK01
EMC emission limit category
+EMC3 : C3 Commercial&Industry Environ
Common mode filter (for DM)
+P000 : No Option
DUT filter (for DM)
+P000 : No Option
Brake chopper
+DBNO : No dynamic braking device
Real time clock option
+SRNO : No Battery for real time clock
Configurable power range
NONE : None
Power connections
+P000 : No Power options (+P000)
Cable entry
+Q000 : No option
Additional Equipment B
+Q000 : No option for Qxxx_B (+Q000)
Additonal Equipment C
+Q000 : No additonal option for Qxxx_C
Shipping package
+GSWP : Wooden box as shipping pack
Marine construction
+E000 : no option
B-Slot Option Board
+SBF3 : F3,3 Relay board
C- Slot Option Board
+SC00 : No board
D-Slot Option Board
+SD00 : No board
E-Slot Option Board
+SE00 : No board
Internal FB selection
+FBM1 : Std protocol,Modbus,N2,BacNet
Documentation level
+DPAP : Paper Manuals
Document language preference
+DLNL : Dutch
Firmware Language Pack
+FL03 : UK, ES, FR, IT, NL, PT lang
Application
+A0000 : No Application
Parameter Set
+L0000 : No application parameter set
Motor parameter default freq
+LS50 : 50 Hz def motor freq settings
Unit for measure for display
+LSSI : Metric Units of Measure
Labeling options
+LPC1 : no additional labels
UL approval
+GNUL : No Ul Approval (+GNUL)
Marine approval
NONE : None
RCM Approval
+GACT : RCM Approval N16307
KC approval
+GAKC : KC Approval
Ukrainian approval
+GAUA : Ukrainian Approval
EAC Approval
+GAEA : EAC Approval
Auxilary power supply
+CAPT : Aux voltage transformer
DC power supply for aux device
+C000 : no option
AC socket for aux devices
+CAPS : 230 VAC socket
Input Devices
+CICO+CIFD : Input contactor w fuse switch
Common mode filter (for ED)
+P000 : no option
DU/DT, Sine filter (for ED)
+P000 : no option
Terminal Options
+CTIO : I/O Terminals
Door Equipments
+C000 : no option
Cabinet heater
+C000 : no option
Cabinet light
+C000 : no option
Motor heater control
+C000 : no option
Emergency stop options
+C000 : no option
Insulation fault sensor
+C000 : no option
Cabling from top
+C000 : no option
Back channel cooling
+C000 : no option
Cabinet Plinth
+CHPL : Base plint 100 mm
Empty extension segment
NONE : None
Standardized cabinet solution
NONE : None
Engineered cabinet solution
NONE : None
Product Group
VACON : VACON
Product Series
0100 : Vacon 100 series
Phase
-3L : 3 Phase AC Input
Customized
+BM2H : Vacon 100-FLOW
Main Circuit
+M000 : NONE
Firmware
+F0159 : Vacon0100-Flow Software pack
Max output frequency
NONE : None
Terminal Box
+T000 : NONE
Bypass Control Operation Mode
NONE : none_
Bypass Input Type
NONE : none_
Bypass power connection type
NONE : none_
CE approval
+GACE : CE Approval (+GACE)
ATEX Approval
NONE : None
County Specific Approval
NONE : None
Warrenty time
+WT01 : Warranty 12/18 months (+WT01)
Frame Size
MR10 : Frame 10
Product Catalog
NO_VIEW : NO VIEW
Modelcode01
VACON0100-3L-0460-5
Modelcode02
-ED-FLOW+IP54+FL03+DLNL+CAPT
Modelcode03
+CAPS+CICO+CIFD+GNUL
Calculated Net Weight [kg]
372.2
Calculated Gross Weight [kg]
373.2
Motor Power Low Overload [kW]
250
Dimensions WxHxD [mm] net
1206 X 2155 X 639
Dimensions WxHxD [mm] Gross
1355 X 2440 X 800
Dimensions WxHxD [mm]
606X2100X600
Continuous Current (NO) [A]
460
Motor Power HP Low Overload
350
Typecode Part 1
70-AB3L04605C10B530BM2H
Typecode Part 2
-00131439
Stockcode part 1
70-AB3L04605C10B530BM2H
Stockcode part 2
-00131439
check if complete
OK
Plant from Orderline
B503
Vendor
ERR01 : Cannot Determine Vendor
Recommended Factory
ERR01 : Cannot Determine Vendor
Help Counter
20
Calculated Net Weight
359
Method
HORIZONTAL
Sub family identification
NONE : Normal customer ordered
ECCN US
3A999.a
ECCN EU
Y901
181B2113
IGBT kit 500V
181B2111
Single adapter board
181B2110
Rectifier board
181B2109
Thyristor protection board 380-500V MR10
181B2108
Power supply board 380-690V for MR10
181B2105
Accessories bag MR10 module
181B2231
Fuse 800A 690VAC size 3 aR
181B1961
Input fuse plain blade 700A aR 690VAC si
181B1959
Fuse 1000A 900VAC
181B1950
Aux power supply 24VDC 60W
181B0586
OPT-E7-V:DeviceNet
181B0761
OPT-EC-V:EtherCAT
181B3287
OPT-EA-V:Advanced 2-port ethernet
181B1472
OPT-B2-V+DLES:1RO(NO/NC),1RO(NO),therm
181B1473
OPT-B4-V+DLES:AI,2AO(mA,isol),+24V/EXT
181B1481
OPT-B1-V+DNOT:6 programmableDI/DO
181B1738
OPT-B4-V+DLFR:AI,2AO(mA,isol),+24V/EXT
181B2134
OPT-B2-V+DLDE:1RO(NO/NC),1RO(NO),therm
181B2151
OPT-B2-V+DNOT:1RO(NO/NC),1RO(NO),therm
181B2152
OPT-B4-V+DNOT:AI,2AO(mA,isol),+24V/EXT
130R1167
DrivePro ExWarr Work Shop PG07 66 Month
130R1162
DrivePro ExWarr Work Shop PG07 36 Month
130R1164
DrivePro ExWarr Work Shop PG07 48 Month
130R1163
DrivePro ExWarr Work Shop PG07 42 Month
130R1165
DrivePro ExWarr Work Shop PG07 54 Month
130R1166
DrivePro ExWarr Work Shop PG07 60 Month
130R1168
DrivePro ExWarr Work Shop PG07 72 Month
130R1160
DrivePro ExWarr Work Shop PG07 24 Month
130R1161
DrivePro ExWarr Work Shop PG07 30 Month
130R1068
DrivePro ExWarr Onsite PG07 72 Months
Get a Quick Quote for a Danfoss 132H2909
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Danfoss 132H2909?
Enquire Now