132L9083

Part Number: 132L9083
Manufacturer
Danfoss
Part number
132L9083

Product Information

Extended Description

132L9083 Danfoss: Frequency converterVACON0100-3L-0386-5-ED-FLOW+SBF4+SDE3+SEBJ+IP54+FL05+DLDE+CAPT+CAPD+CAPS+CPS0+CHPH+GNULVACON 100 FLOW380-500 Vac, 386 Amp, IP54/NEMA12Graphical Keypad MK01C3 Commercial&Industry EnvironB Slot: F4,2 Relay board with thermC Slot: No boardD Slot: E3,PROFIBUS DPFieldbus: Std protocol,Modbus,N2,BacNetManual: GermanFrame 09bE Slot: BJ,STO, ATEX thermATEX: II (2) GDOther options according to Model code
Gross weight
254.3 kg
Net weight
253.3 kg
Volume
0 l
EAN
5714853908707
Product View (Switch)
GLBL : Global (Standard)
Segment
-FLOW : VACON 100 FLOW
Region Code
-R00 : R00 International
Mains voltage
-5 : 380-500 Vac
Current rating
-0386 : 386 Amp
Installation options
-ED : ED Enclosed Drive
Enclosure
+IP54 : IP54/NEMA12
Control panel
+HMGR : Graphical Keypad MK01
EMC emission limit category
+EMC3 : C3 Commercial&Industry Environ
Common mode filter (for DM)
+P000 : No Option
DUT filter (for DM)
+P000 : No Option
Brake chopper
+DBNO : No dynamic braking device
Real time clock option
+SRNO : No Battery for real time clock
Configurable power range
NONE : None
Power connections
+P000 : No Power options (+P000)
Cable entry
+Q000 : No option
Additional Equipment B
+Q000 : No option for Qxxx_B (+Q000)
Additonal Equipment C
+Q000 : No additonal option for Qxxx_C
Shipping package
+GSWP : Wooden box as shipping pack
Marine construction
+E000 : no option
B-Slot Option Board
+SBF4 : F4,2 Relay board with therm
C- Slot Option Board
+SC00 : No board
D-Slot Option Board
+SDE3 : E3,PROFIBUS DP
E-Slot Option Board
+SEBJ : BJ,STO, ATEX therm
Internal FB selection
+FBM1 : Std protocol,Modbus,N2,BacNet
Documentation level
+DPAP : Paper Manuals
Document language preference
+DLDE : German
Firmware Language Pack
+FL05 : UK, DE, EE, HU, RO, TR lang
Application
+A0000 : No Application
Parameter Set
+L0000 : No application parameter set
Motor parameter default freq
+LS50 : 50 Hz def motor freq settings
Unit for measure for display
+LSSI : Metric Units of Measure
Labeling options
+LPC1 : no additional labels
UL approval
+GNUL : No Ul Approval (+GNUL)
Marine approval
NONE : None
RCM Approval
+GACT : RCM Approval N16307
KC approval
+GAKC : KC Approval
Ukrainian approval
+GAUA : Ukrainian Approval
EAC Approval
+GAEA : EAC Approval
Auxilary power supply
+CAPT : Aux voltage transformer
DC power supply for aux device
+CAPD : 24V DC power supply
AC socket for aux devices
+CAPS : 230 VAC socket
Input Devices
+CIFU : (+CIFU) AC fuses
Common mode filter (for ED)
+P000 : no option
DU/DT, Sine filter (for ED)
+P000 : no option
Terminal Options
+CTIO : I/O Terminals
Door Equipments
+C000 : no option
Cabinet heater
+C000 : no option
Cabinet light
+C000 : no option
Motor heater control
+C000 : no option
Emergency stop options
+CPS0 : Emergency Stop Cat0
Insulation fault sensor
+C000 : no option
Cabling from top
+C000 : no option
Back channel cooling
+C000 : no option
Cabinet Plinth
+CHPH : Base plint 200 mm
Empty extension segment
NONE : None
Standardized cabinet solution
NONE : None
Engineered cabinet solution
NONE : None
Product Group
VACON : VACON
Product Series
0100 : Vacon 100 series
Phase
-3L : 3 Phase AC Input
Customized
+BM2H : Vacon 100-FLOW
Main Circuit
+M000 : NONE
Firmware
+F0159 : Vacon0100-Flow Software pack
Max output frequency
NONE : None
Terminal Box
+T000 : NONE
Bypass Control Operation Mode
NONE : none_
Bypass Input Type
NONE : none_
Bypass power connection type
NONE : none_
CE approval
+GACE : CE Approval (+GACE)
ATEX Approval
NONE : None
County Specific Approval
NONE : None
Warrenty time
+WT01 : Warranty 12/18 months (+WT01)
Frame Size
MR09B : Frame 09b
Product Catalog
NO_VIEW : NO VIEW
Modelcode01
VACON0100-3L-0386-5
Modelcode02
-ED-FLOW+SBF4+SDE3+SEBJ+IP54
Modelcode03
+FL05+DLDE+CAPT+CAPD+CAPS+CPS0
Modelcode04
+CHPH+GNUL
Calculated Net Weight [kg]
253.3
Calculated Gross Weight [kg]
254.3
Motor Power Low Overload [kW]
200
Continuous Current (NO) [A]
385
Motor Power HP Low Overload
300
ATEX Marking 1
ATEX: II (2) GD
Typecode Part 1
70-AB3L03865C09B530BM2H
Typecode Part 2
-000065700
check if complete
OK
Plant from Orderline
D801
Vendor
ERR01 : Cannot Determine Vendor
Recommended Factory
ERR01 : Cannot Determine Vendor
Help Counter
10
Sub family identification
NONE : Normal customer ordered
ECCN US
3A999.a
ECCN EU
Y901

Get a Quick Quote for a Danfoss 132L9083

Chat with us on WhatsApp - fast responses guaranteed

Need to speak with someone? We'll call you back within 2 hours during business hours

Interested in Danfoss 132L9083? Enquire Now