Part Number: 137L7671
Product Information
Extended Description
137L7671 Danfoss: Frequency converterVACON0100-3L-1040-5-ED-FLOW+SBF4+IP54+CIFD+GNULVACON 100 FLOW380-500 Vac, 1040 Amp, IP54/NEMA12Graphical Keypad MK01C3 Commercial&Industry EnvironB Slot: F4,2 Relay board with thermC Slot: No boardD Slot: No boardFieldbus: Std protocol,Modbus,N2,BacNetManual: English2xFrame 10E Slot: No boardOther options according to Model code
Gross weight
621.6 kg
Net weight
620.6 kg
Volume
0 l
EAN
5715253552880
Product View (Switch)
GLBL : Global (Standard)
Segment
-FLOW : VACON 100 FLOW
Region Code
-R00 : R00 International
Mains voltage
-5 : 380-500 Vac
Current rating
-1040 : 1040 Amp
Installation options
-ED : ED Enclosed Drive
Enclosure
+IP54 : IP54/NEMA12
Control panel
+HMGR : Graphical Keypad MK01
EMC emission limit category
+EMC3 : C3 Commercial&Industry Environ
Common mode filter (for DM)
+P000 : No Option
DUT filter (for DM)
+P000 : No Option
Brake chopper
+DBNO : No dynamic braking device
Real time clock option
+SRNO : No Battery for real time clock
Configurable power range
NONE : None
Power connections
+P000 : No Power options (+P000)
Cable entry
+Q000 : No option
Additional Equipment B
+Q000 : No option for Qxxx_B (+Q000)
Additonal Equipment C
+Q000 : No additonal option for Qxxx_C
Shipping package
+GSWP : Wooden box as shipping pack
Marine construction
+E000 : no option
B-Slot Option Board
+SBF4 : F4,2 Relay board with therm
C- Slot Option Board
+SC00 : No board
D-Slot Option Board
+SD00 : No board
E-Slot Option Board
+SE00 : No board
Internal FB selection
+FBM1 : Std protocol,Modbus,N2,BacNet
Documentation level
+DPAP : Paper Manuals
Document language preference
+DLUK : English
Firmware Language Pack
+FL01 : UK, DE, FI, SE, IT, FR lang
Application
+A0000 : No Application
Parameter Set
+L0000 : No application parameter set
Motor parameter default freq
+LS50 : 50 Hz def motor freq settings
Unit for measure for display
+LSSI : Metric Units of Measure
Labeling options
+LPC1 : no additional labels
UL approval
+GNUL : No Ul Approval (+GNUL)
Marine approval
NONE : None
RCM Approval
+GACT : RCM Approval N16307
KC approval
+GAKC : KC Approval
Ukrainian approval
+GAUA : Ukrainian Approval
EAC Approval
+GAEA : EAC Approval
Auxilary power supply
+C000 : no option
DC power supply for aux device
+C000 : no option
AC socket for aux devices
+C000 : no option
Input Devices
+CIFD : (+CIFD) Fuse Switch
Common mode filter (for ED)
+P000 : no option
DU/DT, Sine filter (for ED)
+P000 : no option
Terminal Options
+CTIO : I/O Terminals
Door Equipments
+C000 : no option
Cabinet heater
+C000 : no option
Cabinet light
+C000 : no option
Motor heater control
+C000 : no option
Emergency stop options
+C000 : no option
Insulation fault sensor
+C000 : no option
Cabling from top
+C000 : no option
Back channel cooling
+C000 : no option
Cabinet Plinth
+CHPL : Base plint 100 mm
Empty extension segment
NONE : None
Standardized cabinet solution
NONE : None
Engineered cabinet solution
NONE : None
Product Group
VACON : VACON
Product Series
0100 : Vacon 100 series
Phase
-3L : 3 Phase AC Input
Customized
+BM2H : Vacon 100-FLOW
Main Circuit
+M000 : NONE
Firmware
+F0159 : Vacon0100-Flow Software pack
Max output frequency
NONE : None
Terminal Box
+T000 : NONE
Bypass Control Operation Mode
NONE : none_
Bypass Input Type
NONE : none_
Bypass power connection type
NONE : none_
CE approval
+GACE : CE Approval (+GACE)
ATEX Approval
NONE : None
County Specific Approval
NONE : None
Warrenty time
+WT01 : Warranty 12/18 months (+WT01)
Frame Size
MR12 : 2xFrame 10
Product Catalog
NO_VIEW : NO VIEW
Modelcode01
VACON0100-3L-1040-5
Modelcode02
-ED-FLOW+SBF4+IP54+CIFD
Modelcode03
+GNUL
Calculated Net Weight [kg]
620.6
Calculated Gross Weight [kg]
621.6
Motor Power Low Overload [kW]
560
Dimensions WxHxD [mm] net
1206 X 2155 X 639
Dimensions WxHxD [mm] Gross
1355 X 2440 X 800
Continuous Current (NO) [A]
1040
Motor Power HP Low Overload
900
Typecode Part 1
70-AB3L10405C12B530BM2H
Typecode Part 2
-000125818
check if complete
OK
Plant from Orderline
D801
Vendor
ERR01 : Cannot Determine Vendor
Recommended Factory
ERR01 : Cannot Determine Vendor
Help Counter
5
Method
HORIZONTAL
Sub family identification
NONE : Normal customer ordered
ECCN US
3A999.a
ECCN EU
Y901
181B1350
Optical fiber harness kit MR12
181B2110
Rectifier board
181B2105
Accessories bag MR10 module
181B2231
Fuse 800A 690VAC size 3 aR
181B1961
Input fuse plain blade 700A aR 690VAC si
181B1959
Fuse 1000A 900VAC
181B1950
Aux power supply 24VDC 60W
181B1935
Fuse plain blade 500A aR 690VAC size 2
181B1100
Terminal connector kit Vacon100
181B1287
Follower adapter board
181B0586
OPT-E7-V:DeviceNet
181B0761
OPT-EC-V:EtherCAT
181B3287
OPT-EA-V:Advanced 2-port ethernet
181B1472
OPT-B2-V+DLES:1RO(NO/NC),1RO(NO),therm
181B1473
OPT-B4-V+DLES:AI,2AO(mA,isol),+24V/EXT
181B1481
OPT-B1-V+DNOT:6 programmableDI/DO
181B1738
OPT-B4-V+DLFR:AI,2AO(mA,isol),+24V/EXT
181B2134
OPT-B2-V+DLDE:1RO(NO/NC),1RO(NO),therm
181B2151
OPT-B2-V+DNOT:1RO(NO/NC),1RO(NO),therm
181B2152
OPT-B4-V+DNOT:AI,2AO(mA,isol),+24V/EXT
130R1074
DrivePro ExWarr Onsite PG08 48 Months
130R1073
DrivePro ExWarr Onsite PG08 42 Months
130R1075
DrivePro ExWarr Onsite PG08 54 Months
130R1076
DrivePro ExWarr Onsite PG08 60 Months
130R1175
DrivePro ExWarr Work Shop PG08 54 Month
130R1177
DrivePro ExWarr Work Shop PG08 66 Month
130R1178
DrivePro ExWarr Work Shop PG08 72 Month
130R1176
DrivePro ExWarr Work Shop PG08 60 Month
130R1170
DrivePro ExWarr Work Shop PG08 24 Month
130R1172
DrivePro ExWarr Work Shop PG08 36 Month
Encoder-less Safety using DOLD Module
VACON Condition-based Monitoring
VACON=C2=AE 100 FLOW Application Guide
VACON 100 Selection Guide
VACON=C2=AE 100 dUdt Technical Guide
VLT=C2=AE AHF 005-010 FOR VACON=C2=AE 100
HMI Door mounting kit instruction
VACON=C2=AE 100 BACnet Installation Manual
VACON=C2=AE 100 Door Keypad Instruction
VACON=C2=AE 100 Encl. Drive MR12 Add. leaflet
Danfoss MD 00779152 B2
UL E171278
Danfoss EU-UK 00737161 D1
Danfoss EU-UK 00737162 D1
T=C3=9CV 01 205 5216 03-20
BV 43073 B0 BV
DNV GL TAE00000XZ Rev. 5
KR HMB28683-AC002
LR21105512TA
NKK TA20165M
OPTF4_VACON_100
MCAD VACON 100 MR12 ED IP54
OPTBK_VACON_100
VACON=C2=AE 100 INDUSTRIAL Firmware
VACON=C2=AE 100 FLOW Firmware
VACON=C2=AE OPT-E7 DeviceNet Firmware
VACON=C2=AE OPT-EC EtherCAT Firmware
VACON=C2=AE 100 SIMATIC PDM PROFINET IO EDD
VACON=C2=AE OPTE3/E5 PROFIBUS GSD
VACON=C2=AE OPTE6 CANopen EDS
VACON=C2=AE OPTE7 DeviceNet EDS
VACON=C2=AE OPTE9 EtherNet/IP EDS
VACON=C2=AE OPTE9 PROFINET IO GSDML
Get a Quick Quote for a Danfoss 137L7671
Chat with us on WhatsApp - fast responses guaranteed
Need to speak with someone? We'll call you back within 2 hours during business hours
Interested in Danfoss 137L7671?
Enquire Now